Olive Robotics - Technical Docs

2 - Getting Started with the olixSense™ X2 Ultra

Getting Started with the olixSense™ X2 Ultra

Specification source: Official olixSense™ X2 Ultra datasheet, Rev. 3.7, OLV-X2U-DS-0001, 19 October 2026. Connection: page 6; integration: pages 7–9.

Connect and power

Use the approved M12-to-RJ45 cable. Secure the M12 sensor connector and connect RJ45 to an IEEE 802.3af PoE switch or injector. The specified PoE input is 37–57 V DC with end-span / mid-span support. Do not treat power-stage capacity as device consumption; use the order-specific connection drawing.

Configure the host network

For initial setup, place the host on the sensor’s subnet with a unique address. The default sensor address is 192.168.7.100. Use the commissioned address if it has been changed. Open the device address in a browser to access olixOS™. For multiple sensors, assign unique IP addresses and ROS namespaces.

Select mode and output frame

Mode Orientation reference Fusion inputs
IMU Relative to the initialized or user-defined orientation Inertial acceleration and angular rate; magnetometer excluded from orientation
AHRS Magnetometer-aided heading; configurable local zero Inertial measurements plus magnetometer; calibrate in the installed environment

Use FLU (Forward, Left, Up) or FRD (Forward, Right, Down) consistently and apply the physical installation transform. Calibrate bias while stationary. For AHRS, calibrate magnetic measurements in the installed environment. Check active mode and settings after any requested service restart.

Read the ROS 2 stream

Use ROS 2 Humble on the host and match publisher/subscriber QoS. The example namespace is configurable.

ros2 topic list
ros2 topic echo /olive/olixSense/x2/id001/imu --qos-reliability best_effort
Topic suffix Message type Output
imu sensor_msgs/msg/Imu Quaternion, angular velocity, acceleration and covariance
acceleration geometry_msgs/msg/AccelStamped Gravity-compensated acceleration
velocity geometry_msgs/msg/TwistStamped Integrated velocity estimate; use external aiding for sustained estimation
magneticfield sensor_msgs/msg/MagneticField Magnetic field in tesla; auxiliary stream in IMU mode
temperature sensor_msgs/msg/Temperature Internal temperature
status diagnostic_msgs/msg/DiagnosticStatus System diagnostics
/tf tf2_msgs/msg/TFMessage Optional transform publication

The example prefix is /olive/olixSense/x2/id001/; /tf is the optional transform topic. Availability follows the operating mode. Use external aiding for sustained velocity estimation.

Visualize and configure

Use the embedded olixOS™ browser interface for mode, network, namespace, publication rate, calibration and diagnostics. ROS tools such as rqt, RViz2 or PlotJuggler can inspect the published data. Verify timestamps, covariance, gravity handling and the sensor-to-robot transform before estimator integration.

See software development for ROS services, TCP/UDP examples and runtime configuration, and system configuration for shared setup guidance.

Setup and visualization demonstrations

These demonstrations are supplementary; user-interface details can vary with firmware. Use the datasheet-defined connection and mode instructions above.

Back to X2 Ultra Homepage →