Olive Robotics - Technical Docs

3 - Software Development for the olixSense™ X2 Pro

Software Development for the olixSense™ X2 Pro

This page combines the datasheet-defined X2-series interface with firmware-specific integration examples. Confirm optional parameter names and advanced settings against the installed firmware.

Specification source: Official olixSense™ X2 Pro datasheet, Rev. 1.2, OLV-X2P-DS-0001, 19 October 2026. Connectivity: pages 7–8; configuration: page 9.

The examples below use the default component type olixSense and namespace id001. If the namespace is changed in the WebGUI, replace id001 with the configured namespace.

Connection and power

Connect an approved locking USB data cable to the recessed USB-C connector and a data-capable USB host port or powered hub. The nominal supply is 5 V DC; select a source rated for the ordered unit’s current requirement. Allow the ECM/RNDIS USB network interface to enumerate. Power and Ethernet-over-USB data share this cable; this model’s specified interface is not PoE.

Set the host USB adapter to the same subnet as the sensor; the datasheet example is host 192.168.7.1/24 and sensor 192.168.7.100. Verify host support for the selected ECM/RNDIS profile. Use the commissioned address after setup.

Quick Start

Source ROS 2 on your computer or on the device:

source /opt/ros2/humble/install/setup.bash

List nodes and topics:

ros2 node list
ros2 topic list

Read the main IMU stream:

ros2 topic echo /olive/olixSense/x2/id001/imu --qos-reliability best_effort

For high publish rates, use Best Effort QoS when possible. Reliable QoS is useful when every sample matters, but it can add latency or backpressure on slow networks.

ROS 2 Names

Node Names

Node Default ROS 2 node name Purpose
Manager /olive_olixSense_id001_manager Device configuration, services, restart, WebGUI bridge
System /olive_olixSense_id001_system System status and network/device information
IMU /olive_olixSense_id001_imu IMU sensing, fusion, calibration, and data publishing

Default Topic Rule

Default topics use this pattern:

/olive/<component_type>/x2/<namespace>/<publisher_name>

For the default X2-series configuration:

/olive/olixSense/x2/id001/<publisher_name>

Current Topics

Topic Message type Published by Notes
/olive/olixSense/x2/id001/imu sensor_msgs/msg/Imu IMU Main fused IMU output. Contains orientation, angular velocity, and linear acceleration.
/olive/olixSense/x2/id001/acceleration geometry_msgs/msg/AccelStamped IMU Gravity-compensated acceleration.
/olive/olixSense/x2/id001/velocity geometry_msgs/msg/TwistStamped IMU Integrated velocity estimate; use external aiding for sustained velocity estimation.
/olive/olixSense/x2/id001/magneticfield sensor_msgs/msg/MagneticField IMU Magnetic field in tesla; auxiliary stream in IMU mode. Availability follows the operating mode.
/olive/olixSense/x2/id001/temperature sensor_msgs/msg/Temperature IMU Sensor temperature.
/olive/olixSense/x2/id001/status diagnostic_msgs/msg/DiagnosticStatus System Device/system status.
/tf tf2_msgs/msg/TFMessage IMU Only when TF publishing is enabled.

Debug builds or debug mode may publish extra topics such as feedback, imu_1, imu_2, imu_3, imu_4, or imu_5. These are intended for diagnostics and are not the normal integration interface.

Topic Configuration

The WebGUI Topics page can override the main user-facing topic names. Topic changes are stored in:

launch_config_manager.yaml
node.topic_publishers

Configurable publishers:

Node Publisher keys
system status
imu imu, temperature, velocity, magneticfield, acceleration

Each publisher entry has:

Key Type Meaning
publisher_name string Internal/display name for the publisher
use_user_defined bool false uses the Olive default topic rule; true uses user_topic
user_topic string Full ROS 2 topic path, for example /my_robot/imu/data

Topic overrides require a device/service restart before all publishers use the new names.

Services

Service Type Description
/olive/olixSense/x2/id001/setBias std_srvs/srv/Trigger Calibrate bias offsets. Keep the device still while this runs.
/olive/olixSense/x2/id001/setZeroQuaternion std_srvs/srv/Trigger Set the current orientation as the local zero reference.
/olive/olixSense/x2/id001/reboot std_srvs/srv/Trigger Reboot the device.
/olive/olixSense/x2/id001/restartDCMServices std_srvs/srv/Trigger Restart DCM services.
/olive/olixSense/x2/id001/standby std_srvs/srv/SetBool Enable or disable standby behavior.

Examples:

ros2 service call /olive/olixSense/x2/id001/setBias std_srvs/srv/Trigger {}
ros2 service call /olive/olixSense/x2/id001/setZeroQuaternion std_srvs/srv/Trigger {}

Operating Modes

The IMU can run in two main modes:

Mode Use when Notes
AHRS You need magnetometer-aided heading with configurable local zero. Acceleration range is ±4 g. Magnetometer data is included in the orientation solution; calibrate in the installed environment.
IMU You need inertial-relative orientation and configurable accelerometer range. Selectable acceleration ranges: ±2, ±4, ±8, ±16 g. Magnetometer data is excluded from the orientation solution.

Change the mode from the WebGUI IMU debug page. A service restart is required.

Coordinate Systems

The coordinate system is configured from the WebGUI IMU debug page and stored in launch_config_imu.yaml under:

node:
  coordinate_system: FLU_LEGACY

Available modes:

Mode Meaning Notes
FLU_LEGACY Legacy frame behavior Default for compatibility with existing integrations.
FLU ROS-style Forward, Left, Up linear frame Z is converted from the legacy sensor convention.
FRD Forward, Right, Down linear frame Y and Z signs are adjusted from FLU. Common in flight-control integrations.

For new ROS integrations, use FLU unless your stack expects FRD. Keep FLU_LEGACY if you already have deployed software calibrated against the older behavior.

Acceleration Sensitivity

Acceleration sensitivity is configured from the WebGUI IMU debug page:

node:
  sensor_acc_g: 4g

Options are 2g, 4g, 8g, and 16g.

Important behavior:

IMU JSON Socket Export

The main IMU stream can be exported as JSON over UDP or TCP. This is useful for applications that do not use ROS 2, such as PLC gateways, game engines, web services, data loggers, or lightweight scripts.

The X2 device acts as the socket server. Your computer, robot controller, or application connects to the X2 device. The X2 does not open an outgoing connection to your computer.

Enable Socket Export

Open the WebGUI, go to the IMU debug page, then set:

Setting Meaning
Enable Turns JSON socket export on or off.
Protocol Selects UDP or TCP.
Port The port where the X2 listens. Default is 5600.

Apply the setting and restart the device service when the WebGUI asks for it.

The setting is stored in launch_config_imu.yaml:

node:
  socket_export:
    enabled: true
    protocol: UDP
    port: 5600

What Data Is Sent

Each payload contains the same main IMU information as the ROS 2 sensor_msgs/msg/Imu output:

JSON field Meaning
schema Payload schema version. Current value is olive_imu.v1.
frame_id Frame ID used by the IMU output, for example base_link.
stamp.sec, stamp.nanosec ROS-style timestamp.
orientation Quaternion orientation: x, y, z, w.
orientation_covariance 9-value covariance array.
angular_velocity Angular velocity in rad/s.
angular_velocity_covariance 9-value covariance array.
linear_acceleration Linear acceleration in m/s^2.
linear_acceleration_covariance 9-value covariance array.

Example payload:

{
  "schema": "olive_imu.v1",
  "frame_id": "base_link",
  "stamp": { "sec": 0, "nanosec": 0 },
  "orientation": { "x": 0, "y": 0, "z": 0, "w": 1 },
  "orientation_covariance": [0,0,0,0,0,0,0,0,0],
  "angular_velocity": { "x": 0, "y": 0, "z": 0 },
  "angular_velocity_covariance": [0,0,0,0,0,0,0,0,0],
  "linear_acceleration": { "x": 0, "y": 0, "z": 0 },
  "linear_acceleration_covariance": [0,0,0,0,0,0,0,0,0]
}

TCP Client

Use TCP when you want a stream connection and simple line-by-line parsing. Each IMU sample is sent as one newline-delimited JSON object.

Quick test:

nc <device-ip> 5600

Python TCP example:

import json
import socket

HOST = "192.168.7.100"  # X2 device IP
PORT = 5600

with socket.create_connection((HOST, PORT), timeout=5) as sock:
    file = sock.makefile("r")
    for line in file:
        msg = json.loads(line)
        q = msg["orientation"]
        acc = msg["linear_acceleration"]
        gyro = msg["angular_velocity"]

        print(
            "q=({x:.4f}, {y:.4f}, {z:.4f}, {w:.4f}) "
            "acc=({ax:.3f}, {ay:.3f}, {az:.3f}) "
            "gyro=({gx:.3f}, {gy:.3f}, {gz:.3f})".format(
                x=q["x"], y=q["y"], z=q["z"], w=q["w"],
                ax=acc["x"], ay=acc["y"], az=acc["z"],
                gx=gyro["x"], gy=gyro["y"], gz=gyro["z"],
            )
        )

UDP Client

Use UDP when you want lower overhead and can tolerate packet loss. UDP has no connection handshake, so the client must first send any small packet to the X2. This tells the X2 where to send IMU packets back.

Quick test:

echo hello | nc -u <device-ip> 5600

Python UDP example:

import json
import socket

HOST = "192.168.7.100"  # X2 device IP
PORT = 5600

sock = socket.socket(socket.AF_INET, socket.SOCK_DGRAM)
sock.settimeout(5)

# Register this client with the X2. The content is not important.
sock.sendto(b"hello", (HOST, PORT))

while True:
    data, _ = sock.recvfrom(65535)
    msg = json.loads(data.decode("utf-8"))

    q = msg["orientation"]
    acc = msg["linear_acceleration"]
    gyro = msg["angular_velocity"]

    print(
        "q=({x:.4f}, {y:.4f}, {z:.4f}, {w:.4f}) "
        "acc=({ax:.3f}, {ay:.3f}, {az:.3f}) "
        "gyro=({gx:.3f}, {gy:.3f}, {gz:.3f})".format(
            x=q["x"], y=q["y"], z=q["z"], w=q["w"],
            ax=acc["x"], ay=acc["y"], az=acc["z"],
            gx=gyro["x"], gy=gyro["y"], gz=gyro["z"],
        )
    )

Choosing UDP or TCP

Protocol Choose it when Tradeoff
UDP You need low overhead and can accept dropped samples. Packets can be lost or arrive unevenly. Your client must send one registration packet first.
TCP You want a reliable stream and simple newline-delimited JSON parsing. If the receiver is slow, TCP can add latency or backpressure.

For high-rate real-time visualization or control, start with UDP. For logging, debugging, or simple integrations, TCP is often easier.

Runtime Parameters

The WebGUI Parameter page is the recommended way to edit runtime parameters. It shows the active profile values and writes changes to the running ROS 2 parameter service when the target node is available.

CLI examples:

ros2 param list /olive_olixSense_id001_imu
ros2 param set /olive_olixSense_id001_imu publish_rate 200

The Parameter page also protects the user experience after OTA/service restart: if a target node is not available yet, the write is rejected and the WebGUI restores the displayed value.

Datasheet output configuration

Control Range / options Default / behavior
Main IMU publish-rate setting 0–1,000 Hz 100 Hz
Auxiliary publish rate 1–200 Hz 100 Hz
System status rate 0–10 Hz 1 Hz
Acceleration / gyro low-pass 0–500 Hz setting 8 Hz; 0 disables the cutoff filter
Acceleration / gyro EMA gain 0–1 0.92
Publisher QoS Best effort / reliable Best effort
Operating modes IMU / AHRS Inertial-relative / magnetometer-aided fusion
Application profiles Drone / Mobile Robot / Humanoid / Raw Profile-based configuration
Orientation zero At startup / service command Defines the local orientation reference

Publication rate and measurement bandwidth are configured separately. Maximum setting is not guaranteed sustained throughput. The acceleration / gyro EMA and low-pass values above are the datasheet defaults; verify the active profile after configuration.

Advanced firmware parameters

The datasheet does not specify numeric defaults or ranges for the advanced fields below. Names and availability depend on firmware. Inspect the active device configuration rather than treating former profile-specific values as model specifications.

Parameter Type Purpose
enable_tf_publisher bool Enables /tf output.
enable_startup_zero_quaternion bool Zeros orientation at startup for a local reference.
gyro_zero_cutoff_threshold double Clips small angular rates to zero.
acc_scale double Global accelerometer output scale.
gyro_scale double Global gyroscope output scale.
fusion_acc_output_time_constant_sec double Smoothing time constant for fused acceleration output.
fusion_acc_correction_time_constant_sec double Long-term acceleration correction speed.
fusion_acc_temperature_step_gain double Extra acceleration correction during temperature changes.
fusion_acc_base_variance double Baseline acceleration variance for fusion weighting.
fusion_acc_outlier_gate double Acceleration outlier rejection gate.
fusion_acc_max_correction_alpha double Maximum acceleration correction step per cycle.
fusion_gyro_output_time_constant_sec double Smoothing time constant for fused gyro output.
fusion_gyro_correction_time_constant_sec double Long-term gyro correction speed.
fusion_gyro_temperature_step_gain double Extra gyro correction during temperature changes.
fusion_gyro_base_variance double Baseline gyro variance for fusion weighting.
fusion_gyro_outlier_gate double Gyro outlier rejection gate.
fusion_gyro_max_correction_alpha double Maximum gyro correction step per cycle.
mag_cutoff_frequency double Magnetometer low-pass cutoff.
mag_ema_gain double Magnetometer EMA gain.
fusion_gain double Fusion beta gain. Higher is more responsive; lower is smoother.
linear_acc_zero_cutoff_threshold double Clips small gravity-compensated acceleration values to zero.

System Parameters

Name Type Default Range What it does
frequency int 1 0..10 Hz System status publish rate.

Parameter Profiles

X2-series IMU profiles are selected from the WebGUI IMU debug page:

Profile Typical use
drone Faster response for aerial or dynamic motion; select the appropriate active profile.
mobile_robot Ground robot motion with more conservative filtering.
humanoid Body-mounted or walking motion.
raw Less processed output for users who want to filter downstream.

Changing the profile updates the active IMU parameter file and requires a service restart.

Calibration

Bias Calibration

Use setBias or the WebGUI calibration action when the device is completely still. Place the device in its normal mounting orientation before starting calibration.

ros2 service call /olive/olixSense/x2/id001/setBias std_srvs/srv/Trigger {}

Magnetic Calibration

For AHRS operation, calibrate in the installed environment and check for magnetic disturbances. Magnetometer data is excluded from the orientation solution in IMU mode.

Zero Orientation

Use setZeroQuaternion when the current physical orientation should become the local zero orientation.

ros2 service call /olive/olixSense/x2/id001/setZeroQuaternion std_srvs/srv/Trigger {}

Practical Notes


Back to X2 Pro Homepage ->

Measurement ranges and performance reference

Parameter Range / specification Condition
Acceleration ±2, ±4, ±8, ±16 g Selectable in IMU mode; ±4 g in AHRS mode
Angular-rate front end ±125, ±250, ±500, ±1,000, ±2,000 °/s Hardware full-scale options; selectable settings depend on software configuration
Magnetic field ±1,300 µT (x/y); ±2,500 µT (z), typical Native magnetic sensing axes
Temperature Internal temperature data Diagnostic output

For settled-angle RMSE, fused noise and stability, see technical specifications. These performance figures are engineering estimates, with model-specific validation pending; they are not production acceptance guarantees.