Olive Robotics - Technical Docs

2 - Getting Started

Getting Started

Setup

  1. Follow the Quick Start Guide for Olive Robotics robot modules to connect the device and start using it.
  2. For more information about the IMU setup and user interface, refer to the demonstration below:
  3. When the IMU module is correctly connected to your system, you can check that the expected ROS topics are present.

The following ROS topics should be shown:

Patch >= 1733Patch >= 1787Patch >= 2136
  • /olive/imu/id001/filtered_imu
  • /olive/imu/id001/filtered_ahrs
  • /olive/imu/id001/linear_accel
  • /olive/imu/id001/magnetometer
  • /olive/imu/id001/status
  • /olive/imu/id001/temperature
  • /olive/imu/id001/twist
  • /olive/imu/id001/feedback
  • /tf
  • /olive/imu/id001/mpu
  • /olive/imu/id001/ahrs
  • /olive/imu/id001/acceleration
  • /olive/imu/id001/magneticfield
  • /olive/imu/id001/status
  • /olive/imu/id001/temperature
  • /olive/imu/id001/velocity
  • /olive/imu/id001/feedback
  • /tf

IMU Mode:

  • /olive/olixSense/x1/id001/imu
  • /olive/olixSense/x1/id001/magneticfield
  • /olive/olixSense/x1/id001/status
  • /olive/olixSense/x1/id001/temperature
  • /tf

AHRS Mode:

  • /olive/olixSense/x1/id001/acceleration
  • /olive/olixSense/x1/id001/imu
  • /olive/olixSense/x1/id001/status
  • /olive/olixSense/x1/id001/temperature
  • /olive/olixSense/x1/id001/velocity
  • /tf

Data Visualization and Parameter Configuration

The number id001 is your device's default namespace.

By default, the magnetometer is disabled, making the sensor output relative. To enable the magnetometer and perform calculations based on magnetometer calibration, set the operation_mode parameter to IMU

  1. All topics shown are publishers, meaning that they publish data to the ROS network. In the command line interface you can verify that they are in fact publishing data using for example:
    ros2 topic echo /olive/olixSense/x1/id001/imu
  2. Visualize the data using:
    - rqt
    - PlotJuggler
  3. Visualize the data and change the parameters like IP, Topic Name, etc using the embedded web interface. You just need to open your browser on your host computer and enter the IP address of the device. If you didn't change the default IP address, then it must be 192.168.7.100.
  4. Change all ROS related params with rqt or the ros parameter server

Back to X1 Homepage →