Specification source: Official olixSense™ X2 Ultra datasheet, Rev. 3.7, OLV-X2U-DS-0001, 19 October 2026. Mechanical reference: page 10; processing: page 5; ordering: page 11.
Mechanical details
| Mechanical parameter | Nominal value |
|---|---|
| Overall envelope (W × D × H) | 66 × 57 × 42 mm, including mounting tabs and sensor-side connector |
| Housing footprint | 48 × 48 mm |
| Mounting base | 66 × 48 × 4 mm |
| Mounting holes | 4 × Ø4.1 mm |
| Mounting-hole centres | 58 × 28 mm |
| Connector projection | 8.96 mm beyond housing face |
| Housing | Metal enclosure; finish according to ordered configuration |
| Interface | Approved mating cable and order-specific connection drawing |
The virtual measurement origin is at the board centre. Mount to a rigid surface and apply the sensor-to-robot transform. Allow connector access, cable bend clearance and strain relief. Use the controlled drawing for production tolerances.
Downloads
Specification source: Official olixSense™ X2 Ultra datasheet, Rev. 3.7, OLV-X2U-DS-0001, 19 October 2026. Open page 10 for the model-specific enclosure drawing.
For STEP files and order-specific mechanical or connection drawings, use the official resources or request the controlled files for the ordered configuration.
Processing platform
| Resource | Specification |
|---|---|
| Operating system / sensor fusion | olixOS™ / olixAI™ |
| Processor | 8-core, 64-bit CPU; up to 2.2 GHz |
| AI acceleration | Up to 6 TOPS peak |
| Memory | 4 GB |
| Storage | 64 GB eMMC, nominal |
| Configuration | Integrated browser interface |
| Device services | Sensor streaming, calibration, diagnostics and software maintenance |
CPU and AI ratings are peak capabilities; sustained performance depends on workload and thermal conditions.