4 - olixSense™ X2 Ultra Technical Specifications
olixSense™ X2 Ultra Technical Specifications
Specification source: Official olixSense™ X2 Ultra datasheet, Rev. 3.7, OLV-X2U-DS-0001, 19 October 2026. Tables below follow datasheet pages 2–11; retain the stated conditions and qualification status.
Sensing and operating modes
Multi-Redundant MEMS with Advanced Skew-Redundant Geometry Mounting. olixAI™ combines inertial measurements, calibration and filtering into a unified output. The virtual measurement origin is at the board centre, aligned with the central inertial reference frame. Apply the sensor-to-robot installation transform.
| Mode | Orientation reference | Fusion inputs |
|---|---|---|
| IMU | Relative to the initialized or user-defined orientation | Inertial acceleration and angular rate; magnetometer excluded from orientation |
| AHRS | Magnetometer-aided heading; configurable local zero | Inertial measurements plus magnetometer; calibrate in the installed environment |
Measurement ranges (page 4)
| Parameter | Range / specification | Condition |
|---|---|---|
| Acceleration | ±2, ±4, ±8, ±16 g | Selectable in IMU mode; ±4 g in AHRS mode |
| Angular-rate front end | ±125, ±250, ±500, ±1,000, ±2,000 °/s | Hardware full-scale options; selectable settings depend on software configuration |
| Magnetic field | ±1,300 µT (x/y); ±2,500 µT (z), typical | Native magnetic sensing axes |
| Temperature | Internal temperature data | Diagnostic output |
Fused-output performance (page 3)
Specification basis (datasheet page 3): These are engineering estimates, rounded conservatively toward larger error or noise. The < notation denotes an estimated aggregate bound; it is not a measured X2 acceptance limit, a maximum sample error or a production guarantee. Model-specific performance validation remains pending. Performance depends on mode, calibration, temperature, measurement range, bandwidth and installation.
Settled relative orientation · RMSE
| Operating mode | Roll | Pitch | Yaw |
|---|---|---|---|
| AHRS | < 0.4° | < 0.6° | < 0.5° |
| IMU | < 0.4° | < 0.4° | < 0.2° |
Estimated aggregate RMSE for settled single-axis rotations, describing relative angular displacement after motion has stopped.
Moving-platform settled-angle RMSE
| Operating mode | Roll | Pitch | Yaw |
|---|---|---|---|
| AHRS | < 1.1° | < 1.2° | < 1.7° |
| IMU | < 1.1° | < 1.2° | < 1.3° |
Estimated relative-angle error between settled poses on a moving platform. This is not continuous tracking or absolute magnetic-heading accuracy.
Fused inertial noise and stability
| Parameter | Estimated bound | Unit |
|---|---|---|
| Gyroscope noise density | < 0.01 | °/s/√Hz |
| Angle random walk | < 0.6 | °/√h |
| Gyroscope bias instability | < 7 | °/h |
| Accelerometer noise density | < 200 | µg/√Hz |
| Velocity random walk | < 0.11 | m/s/√h |
| Accelerometer bias instability | < 0.001 | m/s² |
Stationary operation at room temperature; estimates represent three-axis means. Allan-derived white-noise coefficients and bias instability are distinct from absolute bias and thermal drift.
Electrical interface and power (pages 5–6)
| Parameter | Specification / condition |
|---|---|
| Network link | 100 Mb/s Ethernet |
| PoE | IEEE 802.3af powered-device input |
| PoE input range | 37–57 V DC; use a compliant power-sourcing device |
| PoE power-stage capacity | 12.95 W; power-stage rating, not device consumption |
| PoE isolation rating | 1.5 kV; power-stage input-to-output isolation |
| Power-feed support | End-span / mid-span; Mode A / Mode B |
| Protection | Short-circuit protection in PoE power stage |
| Connection | M12 sensor connector; approved M12-to-RJ45 cable to PoE switch or injector |
Processing (page 5)
| Resource | Specification |
|---|---|
| Operating system / sensor fusion | olixOS™ / olixAI™ |
| Processor | 8-core, 64-bit CPU; up to 2.2 GHz |
| AI acceleration | Up to 6 TOPS peak |
| Memory | 4 GB |
| Storage | 64 GB eMMC, nominal |
| Configuration | Integrated browser interface |
| Device services | Sensor streaming, calibration, diagnostics and software maintenance |
CPU and AI figures are peak platform capabilities. Sustained performance depends on workload and thermal conditions. Memory, storage and accessories follow the ordered configuration.
Output configuration (page 9)
| Control | Range / options | Default / behavior |
|---|---|---|
| Main IMU publish-rate setting | 0–1,000 Hz | 100 Hz |
| Auxiliary publish rate | 1–200 Hz | 100 Hz |
| System status rate | 0–10 Hz | 1 Hz |
| Acceleration / gyro low-pass | 0–500 Hz setting | 8 Hz; 0 disables the cutoff filter |
| Acceleration / gyro EMA gain | 0–1 | 0.92 |
| Publisher QoS | Best effort / reliable | Best effort |
| Operating modes | IMU / AHRS | Inertial-relative / magnetometer-aided fusion |
| Application profiles | Drone / Mobile Robot / Humanoid / Raw | Profile-based configuration |
| Orientation zero | At startup / service command | Defines the local orientation reference |
Publication-rate setting and measurement bandwidth are separate. Effective throughput depends on configuration and network. Verify active settings after any requested service restart.
Mechanical dimensions (page 10)
| Mechanical parameter | Nominal value |
|---|---|
| Overall envelope (W × D × H) | 66 × 57 × 42 mm, including mounting tabs and sensor-side connector |
| Housing footprint | 48 × 48 mm |
| Mounting base | 66 × 48 × 4 mm |
| Mounting holes | 4 × Ø4.1 mm |
| Mounting-hole centres | 58 × 28 mm |
| Connector projection | 8.96 mm beyond housing face |
| Housing | Metal enclosure; finish according to ordered configuration |
| Interface | Approved mating cable and order-specific connection drawing |
Use the controlled mechanical drawing for production tolerances. Provide connector access, cable bend clearance and strain relief. Overall depth is 56.96 mm, rounded up to the nominal 57 mm envelope.
Environmental design envelope (page 11)
| Parameter | Value |
|---|---|
| Ambient operating temperature | −20 to +60 °C |
| Storage temperature | −20 to +70 °C |
| Relative humidity | 10–90% RH, non-condensing |
Environmental status (page 11): Subsystem-based design envelope; complete-assembly environmental qualification remains pending. Thermal behavior depends on processing load, enclosure conditions and mounting.
Order-specific confirmation