Olive Robotics - Technical Docs

4 - olixSense™ X2 Ultra Technical Specifications​

olixSense™ X2 Ultra Technical Specifications

Specification source: Official olixSense™ X2 Ultra datasheet, Rev. 3.7, OLV-X2U-DS-0001, 19 October 2026. Tables below follow datasheet pages 2–11; retain the stated conditions and qualification status.

Sensing and operating modes

Multi-Redundant MEMS with Advanced Skew-Redundant Geometry Mounting. olixAI™ combines inertial measurements, calibration and filtering into a unified output. The virtual measurement origin is at the board centre, aligned with the central inertial reference frame. Apply the sensor-to-robot installation transform.

Mode Orientation reference Fusion inputs
IMU Relative to the initialized or user-defined orientation Inertial acceleration and angular rate; magnetometer excluded from orientation
AHRS Magnetometer-aided heading; configurable local zero Inertial measurements plus magnetometer; calibrate in the installed environment

Measurement ranges (page 4)

Parameter Range / specification Condition
Acceleration ±2, ±4, ±8, ±16 g Selectable in IMU mode; ±4 g in AHRS mode
Angular-rate front end ±125, ±250, ±500, ±1,000, ±2,000 °/s Hardware full-scale options; selectable settings depend on software configuration
Magnetic field ±1,300 µT (x/y); ±2,500 µT (z), typical Native magnetic sensing axes
Temperature Internal temperature data Diagnostic output

Fused-output performance (page 3)

Specification basis (datasheet page 3): These are engineering estimates, rounded conservatively toward larger error or noise. The < notation denotes an estimated aggregate bound; it is not a measured X2 acceptance limit, a maximum sample error or a production guarantee. Model-specific performance validation remains pending. Performance depends on mode, calibration, temperature, measurement range, bandwidth and installation.

Settled relative orientation · RMSE

Operating mode Roll Pitch Yaw
AHRS < 0.4° < 0.6° < 0.5°
IMU < 0.4° < 0.4° < 0.2°

Estimated aggregate RMSE for settled single-axis rotations, describing relative angular displacement after motion has stopped.

Moving-platform settled-angle RMSE

Operating mode Roll Pitch Yaw
AHRS < 1.1° < 1.2° < 1.7°
IMU < 1.1° < 1.2° < 1.3°

Estimated relative-angle error between settled poses on a moving platform. This is not continuous tracking or absolute magnetic-heading accuracy.

Fused inertial noise and stability

Parameter Estimated bound Unit
Gyroscope noise density < 0.01 °/s/√Hz
Angle random walk < 0.6 °/√h
Gyroscope bias instability < 7 °/h
Accelerometer noise density < 200 µg/√Hz
Velocity random walk < 0.11 m/s/√h
Accelerometer bias instability < 0.001 m/s²

Stationary operation at room temperature; estimates represent three-axis means. Allan-derived white-noise coefficients and bias instability are distinct from absolute bias and thermal drift.

Electrical interface and power (pages 5–6)

Parameter Specification / condition
Network link 100 Mb/s Ethernet
PoE IEEE 802.3af powered-device input
PoE input range 37–57 V DC; use a compliant power-sourcing device
PoE power-stage capacity 12.95 W; power-stage rating, not device consumption
PoE isolation rating 1.5 kV; power-stage input-to-output isolation
Power-feed support End-span / mid-span; Mode A / Mode B
Protection Short-circuit protection in PoE power stage
Connection M12 sensor connector; approved M12-to-RJ45 cable to PoE switch or injector

Processing (page 5)

Resource Specification
Operating system / sensor fusion olixOS™ / olixAI™
Processor 8-core, 64-bit CPU; up to 2.2 GHz
AI acceleration Up to 6 TOPS peak
Memory 4 GB
Storage 64 GB eMMC, nominal
Configuration Integrated browser interface
Device services Sensor streaming, calibration, diagnostics and software maintenance

CPU and AI figures are peak platform capabilities. Sustained performance depends on workload and thermal conditions. Memory, storage and accessories follow the ordered configuration.

Output configuration (page 9)

Control Range / options Default / behavior
Main IMU publish-rate setting 0–1,000 Hz 100 Hz
Auxiliary publish rate 1–200 Hz 100 Hz
System status rate 0–10 Hz 1 Hz
Acceleration / gyro low-pass 0–500 Hz setting 8 Hz; 0 disables the cutoff filter
Acceleration / gyro EMA gain 0–1 0.92
Publisher QoS Best effort / reliable Best effort
Operating modes IMU / AHRS Inertial-relative / magnetometer-aided fusion
Application profiles Drone / Mobile Robot / Humanoid / Raw Profile-based configuration
Orientation zero At startup / service command Defines the local orientation reference

Publication-rate setting and measurement bandwidth are separate. Effective throughput depends on configuration and network. Verify active settings after any requested service restart.

Mechanical dimensions (page 10)

Mechanical parameter Nominal value
Overall envelope (W × D × H) 66 × 57 × 42 mm, including mounting tabs and sensor-side connector
Housing footprint 48 × 48 mm
Mounting base 66 × 48 × 4 mm
Mounting holes 4 × Ø4.1 mm
Mounting-hole centres 58 × 28 mm
Connector projection 8.96 mm beyond housing face
Housing Metal enclosure; finish according to ordered configuration
Interface Approved mating cable and order-specific connection drawing

Use the controlled mechanical drawing for production tolerances. Provide connector access, cable bend clearance and strain relief. Overall depth is 56.96 mm, rounded up to the nominal 57 mm envelope.

Environmental design envelope (page 11)

Parameter Value
Ambient operating temperature −20 to +60 °C
Storage temperature −20 to +70 °C
Relative humidity 10–90% RH, non-condensing

Environmental status (page 11): Subsystem-based design envelope; complete-assembly environmental qualification remains pending. Thermal behavior depends on processing load, enclosure conditions and mounting.

Order-specific confirmation

The datasheet does not specify assembled mass, measured operating power, connector pinout or completed assembly qualification. Request these and the applicable conformity documents with the quotation.