1 - Getting to Know the olixSense™ X2 Ultra
olixSense™ X2 Ultra
Specification source: Official olixSense™ X2 Ultra datasheet, Rev. 3.7, OLV-X2U-DS-0001, 19 October 2026.

Sensor details
Multi-Redundant MEMS with Advanced Skew-Redundant Geometry Mounting. olixAI™ publishes fused orientation, angular velocity and acceleration at a virtual origin at the board centre. olixOS™ provides configuration, diagnostics and network access.
Operating modes
| Mode | Orientation reference | Fusion inputs |
|---|---|---|
| IMU | Relative to the initialized or user-defined orientation | Inertial acceleration and angular rate; magnetometer excluded from orientation |
| AHRS | Magnetometer-aided heading; configurable local zero | Inertial measurements plus magnetometer; calibrate in the installed environment |
For AHRS, perform magnetic calibration in the installed environment and maintain separation from magnets, high-current wiring and ferromagnetic structures. Orientation zero and magnetic heading reference serve different purposes.
Key features
- Main IMU publish-rate setting: 0–1,000 Hz; default 100 Hz. Actual throughput depends on configuration and network.
- 100 Mb/s Ethernet and IEEE 802.3af isolated PoE; 37–57 V DC input.
- Native ROS 2 Humble, DDS topics, TCP / UDP JSON streaming and browser configuration. ROS 1 integration uses a compatible bridge.
- Nominal enclosure: 66 × 57 × 42 mm including mounting tabs and sensor-side connector.
See technical specifications for ranges, performance estimates and environmental qualification status.